Laboratory pH Sensor Accessories

Suitable for PyroScience sensors

Calibration capsules

Optical fibres

Silicon glue

Adapter rings

Accessories for pH Sensors

  • Sensors
  • Sensor spots
  • Flow-through cells
  • Mini sensors
  • Vials

Request Information

4 + 13 =

pH Sensors

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

PHCAL2 Calibration Capsules (pH 2)
For obligatory acid calibration of optical pH sensors. Each capsule results in 100mL calibration solution (PU=10).

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

PHCAL11 Calibration Buffer Capsules (pH 11)
For recommended basic calibration of optical pH sensors. Each capsule results in 100mL calibration buffer solution (PU=10).

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

PHSC-PK8T Additional Sensor Screw Caps
Additional sensor screw caps for simple exchange of the pH sensitive sensor (PU = 4 pieces).

pH Sensor spots

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

SPFIB-BARE Optical Fibre

  • For contactless sensor readout
  • Optical fibre core Ø = 1mm
  • Ca. 1m length
  • With ST-connector and bare fiber end
  • To measure through 0-2mm thick materials
PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

SPFIB-LNS Optical Fibre with Lens

  • For contactless sensor readout
  • Ca. 1m length
  • through thick walled containers
  • Compatible to SPADBAS
  • With ST-connector for FireSting devices
PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

SPADBAS Basic spot adapter

  • For contactless sensor readout
  • Compatible to SPFIB-BARE, PICFIB2 or PICROD2
  • Can be glued with SPGLUE for fixation
  • PU = 4 units
PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

SPGLUE Silicone Glue

  • Transparent silicone glue Elastosil E43, (ca. 90 ml)
  • For fixing sensor spots or SPADBAS at container walls
PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

PHCAL2 Calibration Capsules (pH 2)
For obligatory acid calibration of optical pH sensors. Each capsule results in 100mL calibration solution (PU=10).

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

PHCAL11 Calibration Buffer Capsules (pH 11)
For recommended basic calibration of optical pH sensors. Each capsule results in 100mL calibration buffer solution (PU=10).

pH Flow-Through Cells

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

SPFIB-BARE Optical Fibre

  • For contactless sensor readout
  • Optical fibre core Ø = 1mm
  • Ca. 1m length
  • With ST-connector and bare fiber end
  • To measure through 0-2mm thick materials
PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

PICFIB2 Fibre for Contactless Readout

  • Fibre diameter Ø = 2mm
  • With PICO-connector, ca. 1m length
  • To measure oxygen and optical temperature sensor spots through 0-10mm thick transparent windows
  • To measure pH sensor spots through 0-5mm thick transparent windows
PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

PHCAL2 Calibration Capsules (pH 2)
For obligatory acid calibration of optical pH sensors. Each capsule results in 100mL calibration solution (PU=10).

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters 1)

PHCAL11 Calibration Buffer Capsules (pH 11)
For recommended basic calibration of optical pH sensors. Each capsule results in 100mL calibration buffer solution (PU=10).

pH Mini Sensors

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

PHCAL2 Calibration Capsules (pH 2)
For obligatory acid calibration of optical pH sensors. Each capsule results in 100mL calibration solution (PU=10).

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

PHCAL11 Calibration Buffer Capsules (pH 11)
For recommended basic calibration of optical pH sensors. Each capsule results in 100mL calibration buffer solution (PU=10).

pH Vials

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

ADVIAL20 Adapter Ring

  • Adapter ring for 20mL vials with up to 3 sensors
  • Compatible to SPFIB-BARE and PICFIB2
PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

ADVIAL20-KIT Adapter Ring Kit
This kit for 20ml respiration vials contains:

  • 4 x optical fibre SPFIB-BARE-CL2
  • 4 x Adapter ring ADVIAL20
PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

SEPVIAL20 Septa and lids for 20 ml sensor vials

  • Septa with lids (with and without hole)
  • For replacement in 20mL sensor vials from PyroScience
  • PU = 4 pieces
PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

OXCAL 0% O2 Calibration Capsules
For recommended 0% O2 calibration of optical oxygen sensors. Each capsule results in 50mL calibration solution (PU=10).

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

PHCAL2 Calibration Capsules (pH 2)
For obligatory acid calibration of optical pH sensors. Each capsule results in 100mL calibration solution (PU=10).

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

PHCAL11 Calibration Buffer Capsules (pH 11)
For recommended basic calibration of optical pH sensors. Each capsule results in 100mL calibration buffer solution (PU=10).

PyroScience FireSting Multi-Analyte Laboratory Oxygen and pH Meters

SPFIB-BARE Optical Fibre

  • For contactless sensor readout
  • Optical fibre core Ø = 1mm
  • Ca. 1m length
  • With ST-connector and bare fiber end
  • To measure through 0-2mm thick materials
QCL Scientific
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.