Fibre-Optic Oxygen Mini Sensors

Fixed Fibre Oxygen Mini Sensor
The fibre-optic oxygen sensors from PyroScience feature no oxygen consumption, no stirring sensitivity, an extremely long shelf time, resistance to corrosive environments (e.g. seawater) and are suitable for multiple applications in gas, water and aqueous samples. These fibre-optic mini sensors consist of an optical fiber with a sensor tip diameter of 430 µm. Compared to a micro sensor, this sensor is suited for slightly larger samples, long-term measurements and profiling applications with less spatial resolution requirements.

OXF1100

OXF1100

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
TROXF1100

TROXF1100

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • For high precision measurements close to 0% oxygen
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
TROXF1100-CL4

TROXF1100-CL4

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • For high precision measurements close to 0% oxygen
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
OXF1100-UHS

OXF1100-UHS

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%oxygen) and liquids (DO)
  • Negligible drift, >3 years shelf time
OXF1100-HS

OXF1100-HS

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • High speed response time (t90 < 0.8s)
  • Works in gas (%oxygen) and liquids (DO)
  • Negligible drift, >3 years shelf time
OXF1100-CL4

OXF1100-CL4

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • Negligible drift, >3 years shelf time
OXF1100-OI

OXF1100-OI

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Optically isolated (OI)
  • Works in gas (%oxygen) and liquids (DO)
  • Negligible drift, >3 years shelf time
OXF1100-OI-CL4

OXF1100-OI-CL4

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 2mm
  • Optically isolated (OI)
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)

Retractable Fibre-Optic Oxygen Sensors
These fibre-optic oxygen sensors from PyroScience feature no oxygen consumption, no stirring sensitivity, an extremely long shelf time, resistance to corrosive environments (e.g. seawater) and are suitable for multiple applications in gas, water and aqueous samples. This fiber-optic minisensor consist of an optical fiber with a sensor tip diameter of 430 µm. Compared to a micro sensor, this sensor is suited for slightly larger samples, long-term measurements and profiling applications with less spatial resolution requirements.

OXR430

OXR430

  • Retractable fibre 430µm in diameter
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
TROXR430

TROXR430

  • Retractable fibre 430µm in diameter
  • For high precision measurements close to 0% oxygen
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
OXR430-HS

OXR430-HS

  • Retractable fibre 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXR430-HS-CL4

OXR430-HS-CL4

  • Retractable fibre 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
OXR430-UHS

OXR430-UHS

  • Retractable fibre 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXR430-CL4

OXR430-CL4

  • Retractable fibre 430µm in diameter
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXR430-OI

OXR430-OI

  • Retractable fibre 430µm in diameter
  • Optically isolated (OI)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXR430-OI-CL4

OXR430-OI-CL4

  • Retractable fibre 430µm in diameter
  • Optically isolated (OI)
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption

Protected Tip Oxygen Mini Sensor

The fibre-optic oxygen sensors from PyroScience feature no oxygen consumption, no stirring sensitivity, an extremely long shelf time, resistance to corrosive environments (e.g. seawater) and are suitable for multiple applications in gas, water and aqueous samples. This fibre-optic minisensor consist of an optical fibre with a sensor tip diameter of 430 µm. Compared to a micro sensor, this sensor is suited for slightly larger samples, long-term measurements and profiling applications with less spatial resolution requirements.

OXF500PT

OXF500PT

  • Sensor tip protect by needle
  • Needle diameter 500µm
  • Optimized for measurements in gas
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXF900PT

OXF900PT

  • Protected sensor tip by needle
  • Needle diameter 900µm
  • Optimized for measurements in gas
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXF500PT-OI-CL4

OXF500PT-OI-CL4

  • Sensor tip protect by needle
  • Needle diameter 500µm
  • Optimized for measurements in gas
  • Optically isolated (OI)
  • 4m cable length (CL4)
OXF500PT-OI

OXF500PT-OI

  • Sensor tip protect by needle
  • Needle diameter 500µm
  • Optimized for measurements in gas
  • Optically isolated (OI)
  • No oxygen consumption
OXF900PT-OI

OXF900PT-OI

  • Protected sensor tip by needle
  • Needle diameter 900µm
  • Optimized for measurements in gas
  • Optically isolated (OI)
  • No oxygen consumption

Bare Fibre Oxygen Mini Sensors

These fibre-optic oxygen sensors from PyroScience feature no oxygen consumption, no stirring sensitivity, an extremely long shelf time, resistance to corrosive environments (e.g. seawater) and are suitable for multiple applications in gas, water and aqueous samples. They consist of an optical fiber with a sensor tip diameter of 430 µm. Compared to a micro sensor, this sensor is suited for slightly larger samples, long-term measurements and profiling applications with less spatial resolution requirements.


OXB430

OXB430

  • Optical fibre 430 µm in diameter
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
TROXB430

TROXB430

  • Optical fibre 430µm in diameter
  • For high precision measurements close to 0% oxygen
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
OXB430-UHS

OXB430-UHS

  • Optical fibre 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXB430-HS

OXB430-HS

  • Optical fibre 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXB430-HS-SUB

OXB430-HS-SUB

  • Optical fibre 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXB430-UHS-SUB

OXB430-UHS-SUB

  • Optical fibre 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXB430-UHS-CL4

OXB430-UHS-CL4

  • Optical fibre 430µm in diameter
  • Ultra-high speed response time (t90 < 0.3s)
  • 4m cable length (CL4)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXB430-SUB

OXB430-SUB

  • Optical fibre 430µm in diameter
  • With underwater SUB-connector (SUB)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXB430-OI

OXB430-OI

  • Optical fibre 430µm in diameter
  • High speed response time (t90 < 0.8s)
  • Optically isolated (OI)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Request Information

10 + 10 =