Fibre-Optic Oxygen Micro Sensors

Fixed Fibre-Optic Oxygen Micro Sensors
The fibre-optic oxygen sensors from PyroScience feature no oxygen consumption, no stirring sensitivity, an extremely long shelf time, resistance to corrosive environments (e.g. seawater) and are suitable for multiple applications in gas, water and aqueous samples.

OXF50

OXF50

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
OXF50-UHS

OXF50-UHS

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%oxygen) and liquids (DO)
OXF50-HS

OXF50-HS

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • Works in gas (%oxygen) and liquids (DO)
OXF50-OI

OXF50-OI

  • Fixed sensor tip surrounded by needle
  • Sensor tip protrudes ca. 6mm
  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • Works in gas (%oxygen) and liquids (DO)

Retractable Fibre-Optic Oxygen Micro Sensors

The fibre-optic oxygen sensors from PyroScience feature no oxygen consumption, no stirring sensitivity, an extremely long shelf time, resistance to corrosive environments (e.g. seawater) and are suitable for multiple applications in gas, water and aqueous samples. They consist of an optical fiber (230 µm) with a sensor tip diameter of approximately 50-70 µm. Microsensors are perfectly suited for measurements in small samples and for profile measurements (e.g. in sediments, soils, plant tissue, biofilm) with high spatial resolution (microprofiling).

OXR50

OXR50

  • Retractable fibre 230µm in diameter
  • 50-70µm sharp sensor tip
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXR50-UHS

OXR50-UHS

  • Retractable fibre 230µm in diameter
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
OXR50-HS

OXR50-HS

  • Retractable fibre 230µm in diameter
  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
OXR50-UHS-CL4

OXR50-UHS-CL4

  • Retractable fibre 230µm in diameter
  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
OXR50-CL4

OXR50-CL4

  • Retractable fibre 230µm in diameter
  • 50-70µm sharp sensor tip
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
OXR50-OI-CL4

OXR50-OI-CL4

  • Retractable fibre 230µm in diameter
  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
OXR50-OI

OXR50-OI

  • Retractable fibre 230µm in diameter
  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption

Bare Fibre-Optic Oxygen Micro Sensors

The fibre-optic oxygen sensors from PyroScience feature no oxygen consumption, no stirring sensitivity, an extremely long shelf time, resistance to corrosive environments (e.g. seawater) and are suitable for multiple applications in gas, water and aqueous samples. They consist of an optical fibre (230 µm) with a sensor tip diameter of approximately 50-70 µm. Microsensors are perfectly suited for measurements in small samples and for profile measurements (e.g. in sediments, soils, plant tissue, biofilm) with high spatial resolution (microprofiling).

OXB50

OXB50

  • 50-70µm sharp sensor tip
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXB50-UHS

OXB50-UHS

  • 50-70µm sharp sensor tip
  • Ultra-high speed response time (t90 < 0.3s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXB50-HS

OXB50-HS

  • 50-70µm sharp sensor tip
  • High speed response time (t90 < 0.8s)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXB50-CL4

OXB50-CL4

  • 50-70µm sharp sensor tip
  • 4m cable length (CL4)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXB50-OI

OXB50-OI

  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • Works in gas (%oxygen) and liquids (DO)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time
OXB50-OI-CL4

OXB50-OI-CL4

  • 50-70µm sharp sensor tip
  • Optically isolated (OI)
  • 4m cable length (CL4)
  • No oxygen consumption
  • Negligible drift, >3 years shelf time

Request Information