Sugar Purity Testing Saccharimeters

The Rudolph Research Analytical Autopol IZ and Autopol IIZ

Rudolph Research Autopol IZ and IIZ  Saccahrimeters
Sugar Extraction Saccahrimeter

Polarimeter for sugar testing

Temperature correction

High quality polarizing prisms

Single or dual wavelength

Autopol IZ Sugar Saccharimeter

  • Single wavelength 589 nm
  • Perfect for 0.02º Z applications where budget is critical
  • Popular for applications that do not require ICUMSA measurement at the 880 nm wavelength

Autopol IIZ Dual Wavelength Sugar Saccharimeter

  • Dual wavelength 589 nm and 880 nm
  • For sugar mills that perform sugar purity testing according to the ICUMSA non-lead procedure
  • A budget saving alternative for applications that do not require the accuracy of more expensive saccharimeters

Sugar Purity Testing Software

Optional Purity software is available for use with a separate Windows PC.. The Purity software and a refractometer also allow dilution on a weight/weight or weight/volume basis which can also be prespecified for each sample name. Each program can be labeled with an alphanumeric and assigned to one of the method keys. The factory operator simply presses the preassigned method key to start measurement.

Try Before You Buy
The Autopol IZ and IIZ are available for a short term trial.

Request Information

15 + 12 =

Dual Wavelengths

The most important feature of the Autopol IIZ is the ability to measure at two wavelengths: 589 nm and 880 nm (NIR). Select 589 nm for conventional analysis using chemicals or lead clarifiers, or select 880 nm for polarimetric sugar measurements in the near infrared (NIR). 880 nm is above the absorption level of most dark sugar factory solutions allowing measurement of filtered but non-lead clarified juices. The dark sample measurement bar gets darker in proportion to the darkness of the sample being measured. When the bar is completely dark the instrument has reached its measurement limit.

Dual Wavelength Saccharimeter

Automatic Temperature Correction

Utilizing the temperature probe located in the measurement compartment, temperature correction to 20ºC, 27.5ºC or other user defined temperature is performed easily and automatically by the Autopol IZ and Autopol IIZ.. The probe can be inserted into all 14 style, 40T style, 41T style and 33 style measurement cells.
The Autopol displays the temperature source and type of correction. Utilizing factory programmed temperature coefficients the Autopol can make the following types of temperature corrections:

 

  • A 30° C sucrose sample can be measured by the temperature probe and corrected to 20°C or 27.5°C or a customer defined temperature
  • A 29°C sucrose sample in a Type 14 center fill glass cell can be measured by the temperature probe inside the saccharimeter sample chamber and corrected to 20°C
  • A Quartz Plate measured at 25°C by the chamber temperature probe and then automatically corrected to 20°C
Saccharimeter Temperature Probe
Saccharimeter Automatic Temperature Correction
Saccharimeter Automatic Temperature Control

Temperature Probe Insertion Options

The temperature probe in the sample compartment can be inserted into the polarimeter cell.

Saccharimeter_Temperature_Probe

Automation and Continuous Sampling

Cells are available in 25mm, 50mm, 100mm and 200mm optical path lengths with fittings for any application.

Saccharimeter_Automation_and_Continuous_Sampling

Pour in Sampling

Stainless steel cells are available in 50mm, 100mm and 200mm optical path lengths.

Saccharimeter_Pour_In_Sampling

Optics

No matter which Autopol saccharimeter you choose it will feature the same high quality optics. While other manufacturers use Polaroid plastic dichroic sheet polarizers, Rudolph Research employ Glan Thompson Calcite polarizers in all its models. High quality polarizing prisms are important because they are two of the most critical optical components in a saccharimeter. Polaroid polarizers are made of a polymeric plastic where the molecules are stretches and oriented in a specific direction so as to linearly polarize light. These types of plastic sheet polarizers are cheap, vulnerable to heat and warping, deteriorate from moisture and have greater light absorption than Calcite polarizers. In many cases the plastic polarizers must be replaced in as little as 3 years whereas Rudolph guarantees its prisms over the life of the Saccharimeter. Glan Thompson calcite polarizers are comprised of a carbon crystalline structure similar to diamond and have excellent light transmission characteristics. The quality of these prisms is such that they are guaranteed over the life of the saccharimeter.

Autopol High quality polarizing prisms

Download Literature

Specifications

Specifications* Autopol IZ

Optical Wavelength: 589nm
Wavelength Selection: Fixed
Measuring Mode: Sugar Degrees, °Z (ISS), User Defined Scale Purity % Sugar
Measuring Range: ±89.99° Arc Optical Rotation, ±259 °Z (ISS)
Resolution: 0.01° Arc Optical Rotation, 0.01 °Z (ISS)
Reproducibility: 0.01° Arc Optical Rotation, 0.01 °Z (ISS)
Accuracy: 0.02° Z
Measuring Scale: Degrees Arc Optical Rotation, °Z (ISS)
Prism Glan: Thompson Calcite
Temperature Control: By external Water Bath
Temperature Correction: 18°C – 40°C
TempTrol™ Accuracy: Temperature accuracy determined by Water Bath
Temperature Probe Range: 10° – 40°C
Temperature Probe Accuracy: ±0.1°C
Measurement Time: 5 measurements in less than 30 seconds (average)
Light Source Standard: Tungsten-Halogen 6V, 20W, average 2,000 hour life
Light Source Optional: LED 20-30 mA 100,000 hr. avg. life
Sample Chamber: Accepts sample tubes up to 200 mm
Data Storage: 32 GB SSD
Communication Interface: 1 x Serial, 1 x VGA, 1 x HDMI, 2 x Cat 5, 4 x USB ports1
Calibration: Automatic calibration via touch screen
Purity Software: Standard
Connection to Refractometer: Standard
Display: 8” diagonal, color, 800 x 600 pixel resolution with 400 nits of brightness
User Interface: Touchscreen
Automatic Sensitivity Control at 589nm: Measures samples with transmittance as low as .1% (up to OD 3.0)*
Input Power: 100 – 240V, 50/60 Hz
Dimensions: 617 mm W x 323 mm H x 445 mm D
Weight: 19.05 kg

*Unless otherwise stated, specifications are based on 589nm

Specifications* Autopol IIZ

Optical Wavelengths: 589nm, 880nm
Wavelength Selection: Selectable: 2 Standard, 4 optional
Measuring Mode: Sugar Degrees, °Z (ISS), User Defined Scale, Purity % Sugar
Measuring Range: ±89.99° Arc Optical Rotation, ±259 °Z (ISS)
Resolution: 0.01° Arc Optical Rotation, 0.01 °Z (ISS)
Reproducibility: 0.01° Arc Optical Rotation, 0.01 °Z (ISS)
Accuracy: 0.02°Z (ISS)
Measuring Scale: Degrees Arc Optical Rotation, °Z (ISS)
Prism Glan: Thompson Calcite
Temperature Control: By external Water Bath
Temperature Correction: 18°C – 40°C
TempTrol™ Accuracy: Temperature accuracy determined by Water Bath
Temperature Probe Range: 10° – 40°C
Temperature Probe Accuracy: ±0.1°C
Measurement Time: 5 measurements in less than 30 seconds (average)
Light Source Standard: Tungsten-Halogen 6V, 20W, average 2,000 hour life
Light Source Optional: Not Available
Sample Chamber: Accepts sample tubes up to 200 mm
Data Storage: 32 GB SSD
Communication Interface: 1 x Serial, 1 x VGA, 1 x HDMI, 2 x Cat 5, 4 x USB ports1
Calibration: Automatic calibration via touch screen
Purity Software: Standard
Connection to Refractometer: Standard
Display: 8” diagonal, color, 800 x 600 pixel resolution with 400 nits of brightness
User Interface: Touchscreen
Automatic Sensitivity Control at 589nm: Measures samples with transmittance as low as .1% (up to OD 3.0)*
Input Power: 100 – 240V, 50/60 Hz
Dimensions: 617 mm W x 323 mm H x 445 mm D
Weight: 19.05 kg

*Unless otherwise stated, specifications are based on 589nm

QCL Scientific
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.