QCL
QCL QCL
 
Home
About Us
Contact
Ordering
Service
User Guides
Brochures
Newsletters
MSDS
Links
Terms & Conditions
 
Partner With QCL
Adobe Acrobat
Download Adobe
Acrobat reader
TitraLab 865  

The TitraLab 865 gives instant access to routine functions, making it by far the simplest titrator of its generation. Pre-set routines guide you when running analyses, repeating measurements and performing maintenance. The titration curve is easy to follow live on the large graphic display together with electrode and titrant status. Measurements can be automatically sequenced and repeated, ideal for direct measurement followed by a titration.

The titrating burettes offer the highest resolution on the market giving unbeatable accuracy for your potentiometric titrations. Reach end points or determine inflection points even more quickly, whether you are working with sharp or weak curves or running single or multiple IP, detection is fast and reliable. The TitraLab 865 is also the first titrator of its kind to offer full Quality Controls on your results. QC samples can be defined at specific intervals with full traceability and result archiving.

Applications
Food & Beverage Peroxide number: edible fats and oils
Chloride: milk, butter, other dairy products
Ascorbic acid: fruit juice and food
Environment and Water pH, Alkalinity and Hardness
Calcium and Magnesium
Sulphate
Chemical Oxygen Demand
Chemical and Pharmaceutical Acid-base titrations in aqueous/non-aqueous media
Redox titrations
Karl Fischer
Petrochemical TAN/TBN: according to ASTM D664, D2896
Bromine Index and Bromine Number: according to ASTM D1159, D2710 & D5776
Mercaptans: according to ASTM D3227

Technical Specification

Methods End point titration: 1 to 4 pre-set end points.
Inflection point titration: Auto determination of 1 to 8 inflection points with programmable IP acceptation windows.
IP detection using 1st and 2nd derivative curve.
Titration stops at: pH, mV, ml, IP number.
Titrant addition techniques: incremental dynamic, incremental monotonic and continuous dynamic.
Titrant calibration.
pH electrode calibration: up to 5 points using IUPAC standards or 4-7-10 Series buffers with error recognition on buffer used.
Direct pH/mV measurements with recording on stable reading.
Back titration with manual or automatic reagent addition (with ABU52).
Sequencing of up to 10 methods.
Coupling of 2 to 4 methods in one beaker.
Measuring Range/Resolution 9 to 23 pH 0.001 pH
±2000 mV 0.1 mV
10°C to +100°C 0.1°C
Printout Automatic. GLP compliant.
Selectable: no, 80 columns.
Detailed or condensed.
Results In each method, calculation of up to 8 results and 2 user-defined equations.
QC check on results with visual warning.
Statistical calculations.
Units All standard units for samples/results.
User-defined result units.
Storage capacity Global password protection for programming access.
Non-volatile memory.
User programmable: 50 methods.
Libraries for 30 electrodes and 30 reagents: more than 30 electrodes and 20 titrants pre-identified with ID and type to help programming.
Storage of 200 results.
Stored parameters characterised by own ID, location and calibration data.
Embedded operating procedures for electrode and reagent exchange.
Automatic electrode, titrant calibration and QC prompt.
Sample list Up to 126 data with alphanumeric ID.
QC sample definition.
Electrode Stand- Stirring Magnetic stirrer, 22 reproducible speeds
(0 to 1100 rpm) in 50 rpm steps.
Propeller connection.
Beaker volume: 5 to 400 ml.
Burette 2 embedded burette stands.
Burette volumes available: 1, 5, 10, 25, 50 ml.
Burette motor: 18000 steps.
Complies with ISO/FDIS 8655-3.
Burette extension: 4 (with ABU52).
UV-protected encapsulated glass syringe.
Embedded operating procedures for burette exchange, air bubble removal (Flush).
Rinse, Fill, Empty function.
Inputs/outputs 2 indicator electrode inputs.
1 reference electrode input.
Selectable polarised input from -1 mA to 1 mA in 1 µA steps, DC or AC.
Differential input.
Temperature input.
0-5 V TTL output.
0-12 V TTL output.
Serial connections for Printer/PC, balance and additional titrator for use with TitraMaster 85 • PC Software.
Burette extension (with ABU52).
Serial connection for sample changer fitted with 10 to 126-position tray.
PS/2 port for PC keyboard and/or barcode reader.
Languages English, German, Danish and French (other languages, please contact us).
Casing Fully splashproof polypropylene.
Graphic 128x128 dot LCD and alphanumeric keypad.
Dimensions (H x W x D) 380 x 230 x 450 mm (excl. tubing).
Weight 5 kg (excluding reagent bottles).
CE Marking Complies with EMC directive 89/336/EEC
Complies with LV directive 73/23/EEC
Power requirements 47.5 - 63 Hz 115/230 Vac +15 -18%.
Environmental conditions 5 to 40°C temperature.
20 to 80% relative humidity.

For further information on this product please contact the product manager, Ivan Saunders on 01342 820820 or email enquiries@qclscientific.com.

  TitraLab 865
TitraLab 865 Brochure
  TitraLab Software
TitraLab
Software
 
         
  TitraLab
TitraLab Catalogue
  Acidity of Milk
Acidity of Milk
 
         
  Acidity of Cheese
Acidity of Cheese
  Iodine value of Animal and Vegetable Fats and Oils
Iodine Value of Fats and Oils
 
         
  Peroxide Number of Edible Oils
Peroxide No. of Edible Oils
  Acidity of Wines or Juices
Acidity of Wines / Juices
 

TitraLab 865
Click image to enlarge

 

QCL