Welland Range Incubators: 80°C  

Available with a maximum operating temperature of 80°C and a minimum operating temperature of 10°C above ambient. Both gravity and forced convection models are available. All units have an integral sealed glass door to facilitate product inspection and are designed for long term accuracy and reliability. A wide choice of control and programming options is available. Heat up times are excellent and temperature stability, with microprocessor three term control, varies from + 0.2°C to + 0.5°C, depending on the model type.

Technical Specification
Fan Circulation Models WIF 30 WIF 60 WIF 120 WIF 200
Maximum temperature (°C) 80 80 80 80
Chamber dimensions (mm - h x w x d) 300 x 292 x 320 400 x 392 x 420 500 x 492 x 520 750 x 592 x 520
External dimensions (mm - h x w x d) 470 x 665 x 470 570 x 765 x 570 5670 x 865 x 670 920 x 965 x 670
Volume (l) 28 66 128 230
Number of shelves supplied 2 2 2 2
Maximum possible number of shelves 3 5 9 15
Maximum shelf load (kg) 10 10 10 10
Maximum load (kg) 20 30 40 50
Power rating at 240V (W) 250 675 675 1000
Temperature uniformity at maximum temperature as a percentage +/- 1.5 +/- 1.5 +/- 1.5 +/- 1.5
Temperature stability (°C): PID control +/- 0.2 +/- 0.2 +/- 0.2 +/- 0.2
Heat up time to 37°C (mins) 6.5 6.5 6.5 8
Heat up time to 80°C (mins) 18 18 18 25
Recovery time to 37°C 1 0.5 1 0.5
Recovery time to 80°C 3.5 1.5 2.5 5
Air exchanges / hour 50 21 11 6
Air exchanges / hour (litres) 1400 1400 1400 1400
Weight (kg) 30 45 60 75
         
Natural Circulation Models WIN 30 WIN 60 WIN 120 WIN 200
Maximum temperature (°C) 80 80 80 80
Chamber dimensions (mm - h x w x d) 255 x 330 x 320 350 x 392 x 420 450 x 492 x 520 700 x 592 x 520
External dimensions (mm - h x w x d) 470 x 665 x 470 570 x 765 x 570 670 x 865 x 670 920 x 965 x 670
Volume (l) 27 58 115 215
Number of shelves supplied 2 2 2 2
Maximum possible number of shelves 3 5 9 15
Maximum shelf load (kg) 10 10 10 10
Maximum load (kg) 20 30 40 50
Power rating at 240V (W) 250 550 675 1000
Temperature uniformity at maximum temperature as a percentage +/- 3.5 +/- 3.5 +/- 3.5 +/- 3.5
Temperature stability (°C): PID control +/- 0.5 +/- 0.5 +/- 0.5 +/- 0.5
Heat up time to 37°C (mins) 6.5 6.5 6.5 8
Heat up time to 80°C (mins) 18 18 18 25
Recovery time to 37°C 0.5 1 2 2.5
Recovery time to 80°C 1.5 3 4.5 6
Weight (kg) 30 45 60 75

Welland Range Ovens: 300°C