Orion Steam Sample Conditioner


• The 1803 can handle pressures of up to 20,897 K Pa (3030 psi). The usual average pressure of process steam is approximately 6,896 K Pa (1000 psi).
• The 1803 can reduce the temperature of the sample from 538°C (1000°F) to under 38°C (100°F).
• No electrical requirements - the 1803 is purely mechanical, requiring no electrical hook up. This means that it can be used in multiple countries regardless of the voltage requirements. The 1803 can also be used in hazardous locations without any danger of explosion.
• The 1803 has a mechanical temperature shut off valve which will trip if the temperature exceeds 40°C (104°F). This can happen when a cooler fails or the cooling water becomes too hot. The valve diverts the hot sample away from the On-Line monitor, avoiding costly damage. Features:
• Thermal shut off valve
• Sample cooler
• Pressure reduction element
• Temperature indicator
• Back pressure relief valve
Markets:
• Power
• Pulp and Paper
• Chem / Petrochemical
Applications:
• Reduce temperature and pressure of steam samples
Specifications:

Temperature

up to 538°C (1000°F)

Pressure

20,897 K Pa (3030 psi)

Panels Dimensions

30.5x91.5x17 cm (12x36x6.5 in)

Materials

Stainless Steel